Photo: Mtaylor848 · CC BY-SA 3.0 · Image credits
Instrumentation & Sensors
Flanged Electromagnetic Flow Meter
Model: FM-EM
Flow meter for conductive liquids with no moving parts and no pressure drop, 0.5 % accuracy.
- 0.5 % of reading accuracy
- No moving parts, no pressure loss
- 4–20 mA, pulse and Modbus outputs
- Local display and totaliser
Nationwide delivery · Free technical advice
Nominal sizeDN10 – DN1000
Accuracy±0.5 % of reading
Measuring range0.03 – 12 m/s
Turndown ratio400 : 1
Overview
The FM-EM applies Faraday's law to measure the volumetric flow of conductive liquids — no moving parts, no pressure drop and no sensitivity to temperature or density. PTFE or rubber lining and stainless or Hastelloy electrodes suit water, wastewater and slurries.
Technical specifications
General
- Nominal size
- DN10 – DN1000
- Accuracy
- ±0.5 % of reading
- Measuring range
- 0.03 – 12 m/s
- Turndown ratio
- 400 : 1
Materials & construction
- Lining
- PTFE · PFA · Hard rubber
- Electrodes
- AISI 316L · Hastelloy C · Ti
- Body material
- Carbon steel / SS
Process conditions
- Pressure rating
- PN10 – PN40
- Operating temperature
- −20 … +150 °C
- Protection
- IP67 / IP68 (remote)
Communication
- Output
- 4–20 mA · Pulse · Modbus · HART
Applications
Water and wastewater networks
Food and chemical industries
Chiller and cooling-tower loops
Sludge and slurry
Need help selecting or pricing?